Illustrated title card for the guide: Beelink Mini S12 Pro & EQ14 Proxmox Plex iGPU Setup
proxmox-setup

Beelink Mini S12 Pro & EQ14 Proxmox Plex iGPU Setup

Proxmox VE iGPU setup for Beelink EQ14 and Mini S12 Pro owners. Check host support, then pass a render device into LXC for Plex or Jellyfin.

For a Beelink Mini S12 Pro or EQ14 running Proxmox VE, use this passthrough workflow if the host exposes an Intel render device such as /dev/dri/renderD128 and supports the dev[n] option. Pass the device into an unprivileged LXC with the container’s group ID, then verify hardware acceleration for Plex or Jellyfin.

Alder Lake-N Codec Support

For Alder Lake-N (ADL-N), Intel’s Graphics Media Driver TGLx matrix lists hardware decoding and encoding for AVC and for some HEVC profiles. For VP9, the matrix lists hardware decoding and encoding at 8-bit and 10-bit, and decoding only at 12-bit. The Full Feature Build also lists 8-bit and 10-bit AV1 decoding. The Jellyfin Intel hardware acceleration guide lists Arc A-series (DG2) and Meteor Lake among the Intel graphics platforms that support 8-bit and 10-bit hardware AV1 encoding.

CodecHardware DecodeHardware Encode
AVC (H.264)SupportedSupported
HEVC (H.265)Supported for the listed profilesVaries by profile and driver build
VP98-bit, 10-bit, and 12-bit8-bit and 10-bit
AV1 (8-bit and 10-bit)Supported in the Full Feature BuildNot supported

Memory and Filesystem Planning for Proxmox VE

The Proxmox VE installation documentation recommends at least 2 GB of RAM for the OS and Proxmox VE services, plus memory for guests. For ZFS, Proxmox recommends roughly 1 GB of additional RAM per TB of used storage. For VM storage, Proxmox recommends SSDs with power-loss protection (PLP) and discourages consumer SSDs.

Install Proxmox VE on the Mini PC

Follow the Proxmox VE installation guide to prepare the host before creating containers:

  1. Download the official Proxmox VE ISO and write it to a USB flash drive.
  2. In the mini PC firmware settings, enable booting from USB. If you plan to run KVM virtual machines, check that the CPU and motherboard support Intel VT.
  3. Disable Secure Boot in UEFI when booting an installer prior to Proxmox VE 8.1.
  4. Boot from the USB drive and select Install Proxmox VE (Graphical).
  5. The installer formats the target disks and erases their data. Check that the disks contain no data you need before proceeding. Choose the target drive and filesystem (ext4, XFS, ZFS, or BTRFS as a technology preview). Then set your location, time zone, keyboard layout, root password, email, and management network settings.
  6. Remove the USB drive when the installer finishes, let the host reboot, and open https://<your-ip-address>:8006 in a browser.
  7. Sign in with username root under the PAM realm.

Verify the Intel iGPU and i915 Driver on the Host

Before configuring an LXC container, confirm in the Proxmox host shell that the Linux i915 driver is bound to the Intel GPU and that the DRI device nodes exist.

Run the PCI check documented in the official Plex Docker repository:

lspci -v -s $(lspci | grep VGA | cut -d" " -f 1)

Verify that the output includes Kernel driver in use: i915. Next, list the DRI devices as shown in the Jellyfin Intel hardware acceleration guide:

ls -l /dev/dri

Confirm that a render device such as /dev/dri/renderD128 appears in the listing. Note the exact render device name if more than one graphics adapter is present.

Intel’s Media Driver documentation says supported kernels load HuC firmware by default on Alder Lake-N if the matching firmware binary is present.

Pass /dev/dri Into an Unprivileged LXC Container

Unprivileged LXC containers use Linux user namespaces to map container IDs to a different range on the host. As documented in the Proxmox VE Linux Container guide and the Unprivileged LXC containers wiki, container UID 0 usually maps to host UID 100000.

Set the option’s gid to the group ID that should own /dev/dri/renderD128 inside the container.

Find the Container’s Device Group ID

In the running unprivileged LXC, find the numeric GID of the group you want to own the render device by reading /etc/group, as shown in Jellyfin’s Proxmox instructions. Jellyfin uses render in its example. Some releases use video or input.

Attach the Render Device via CLI

The current pct.conf(5) manual gives the device passthrough syntax below.

dev[n]: [[path=]<Path>] [,deny-write=<1|0>] [,gid=<integer>] [,mode=<Octal access mode>] [,uid=<integer>]

In that manual, deny-write defaults to 0, so the option leaves writes enabled. On the Proxmox host, use pct set and pct reboot from pct(1). Replace <CTID> with your numeric container ID and <DEVICE_GID> with the number you looked up in /etc/group inside the LXC. If your host exposes a different render device, substitute its path for /dev/dri/renderD128.

pct set <CTID> --dev0 /dev/dri/renderD128,gid=<DEVICE_GID>
pct reboot <CTID>

Inspect /etc/pve/lxc/<CTID>.conf to verify that Proxmox wrote the expected entry:

dev0: /dev/dri/renderD128,gid=<DEVICE_GID>

You can also pass optional uid=<integer> or mode=<octal> parameters if a specific service requires custom ownership or octal permissions.

Attach the Render Device via the Proxmox Web UI

If your Proxmox Web UI offers Device Passthrough, sign in as root to configure it.

  1. Open Resources for your LXC container.
  2. Set up Device Passthrough for /dev/dri/renderD128.
  3. Set the numeric GID you looked up inside the container in the dialog’s advanced options.
  4. Reboot the container.

Legacy Proxmox VE 7.x Note

For Proxmox VE 7 and older, the Jellyfin Intel documentation describes using a privileged LXC and bind-mounting the render device through /etc/pve/lxc/<CTID>.conf.

Verify VA-API Drivers and Hardware Acceleration

After the container reboots, confirm that /dev/dri/renderD128 appears inside the LXC and that the Intel iHD VA-API user-space driver loads.

Check the Intel iHD VA-API Driver Inside the LXC

Intel’s Graphics Media Driver documentation lists Alder Lake-N among the platforms supported by the iHD driver. The Jellyfin Intel hardware acceleration guide identifies iHD as supporting QSV and VA-API. The jellyfin-ffmpeg package bundles the user-mode iHD driver.

In a 64-bit Debian or Ubuntu LXC with the Jellyfin APT repository configured and jellyfin-server and jellyfin-web installed, install jellyfin-ffmpeg8 and list the render device and its group.

sudo apt update && sudo apt install -y jellyfin-ffmpeg8
ls -l /dev/dri

Add the jellyfin service user to the group that owns the render device and restart Jellyfin. Replace render below if the device belongs to a different group.

sudo usermod -aG render jellyfin
sudo systemctl restart jellyfin

Run Jellyfin’s bundled vainfo inside the LXC. Use the render device path from the listing if it differs from the example. Look for iHD in the driver version and check the supported profiles and entrypoints.

sudo /usr/lib/jellyfin-ffmpeg/vainfo --display drm --device /dev/dri/renderD128

Monitor Active GPU Transcoding From the Host

To check Intel GPU activity during transcoding, install intel-gpu-tools from a root shell on the Proxmox host as described in the Jellyfin Intel guide.

apt update && apt install -y intel-gpu-tools

After enabling hardware acceleration in Jellyfin, play a video in its web client and select a lower resolution or bitrate to trigger video transcoding. Then run this command on the Proxmox host as root while the video plays.

intel_gpu_top

Watch Video in intel_gpu_top for decoder or encoder activity. VideoEnhance shows video processing activity.

Enable Quick Sync in Plex or Jellyfin

Once the render device is present inside the LXC, follow the setup for your media server.

Plex Media Server

Per the official plexinc/pms-docker documentation, Intel Quick Sync hardware transcoding in Plex Docker requires access to a supported Intel CPU and an active Plex Pass subscription.

Run Docker inside the unprivileged LXC in this example. The LXC is the Docker host, and Plex documents a newer 64-bit Ubuntu or Fedora system for Quick Sync support. Make sure /dev/dri is available inside the LXC before starting Plex.

The Proxmox pct.conf(5) manual lists keyctl as required for Docker in an unprivileged LXC. It also lists a separate nesting feature, which the Linux Container guide describes as exposing procfs and sysfs to allow nested containers. Both features default to 0. The Plex Docker container runs nested inside the LXC, so enable both.

On the Proxmox host, set keyctl=1 and nesting=1 on the LXC’s features line in /etc/pve/lxc/<CTID>.conf. If the line is absent, add features: keyctl=1,nesting=1. Keep any other entries on an existing line and reboot the LXC to apply the change. The pct.conf(5) manual notes that nesting exposes procfs and sysfs contents of the host to the guest.

In the LXC, replace <timezone> with your time zone and <claimToken> with your Plex claim token. Replace the three <path/to/...> placeholders with paths inside the LXC for Plex configuration, temporary transcoding files, and media, respectively. The --device option passes the device directory from the LXC into the Plex Docker container.

docker run -d \
  --name plex \
  --network=host \
  -e TZ="<timezone>" \
  -e PLEX_CLAIM="<claimToken>" \
  -v <path/to/plex/database>:/config \
  -v <path/to/transcode/temp>:/transcode \
  -v <path/to/media>:/data \
  --device=/dev/dri:/dev/dri \
  plexinc/pms-docker

Then enable hardware transcoding in the Plex Web app:

  1. Open the Plex Web app and navigate to Settings > Server > Transcoder.
  2. Turn on Show Advanced in the upper-right corner.
  3. Turn on Use hardware acceleration when available.
  4. Click Save Changes.

Jellyfin

After checking the render device with Jellyfin’s bundled vainfo, configure the Jellyfin Web UI:

  1. In the Jellyfin dashboard, enable QSV or VA-API.
  2. Use the same render device path you checked with vainfo.
  3. Uncheck unsupported codecs.

Quick Troubleshooting Checklist

SymptomCheck and Fix
vainfo returns permission denied in LXCCompare the device group from pct exec <CTID> -- ls -l /dev/dri with the group you chose inside the container. Check the device’s gid= and, for Jellyfin, the service user’s group membership.
/dev/dri/renderD128 missing inside LXCRun pct reboot <CTID> to apply pending container changes, and confirm the device exists with ls -l /dev/dri on the host.
Plex Docker hardware transcoding is unavailableVerify Plex Pass status and re-check Settings > Server > Transcoder.

Who This Setup Suits

  • Who it suits: Proxmox VE hosts that expose an Intel render device for transcoding in an unprivileged LXC.

Evidence and Limits

This guide is based on the Proxmox VE 9.3.1 manuals and documentation from Intel Media Driver, Jellyfin, and Plex. This guide is not based on hands-on testing. Browse the BeelinkGuide posts index.

Sources

  1. Proxmox VE Documentation: Installation
  2. Proxmox VE Documentation: Linux Container
  3. Proxmox VE Wiki: Unprivileged LXC Containers
  4. Proxmox VE Manual: pct.conf(5)
  5. Proxmox VE Manual: pct(1)
  6. Jellyfin Documentation: Intel Hardware Acceleration
  7. Intel Graphics Media Driver (intel/media-driver)
  8. Official Plex Media Server Docker Repository (plexinc/pms-docker)

Related